A203

OMA0650

1485,00  VAT 0%

In stock (can be backordered)

Note! Please write desired printed user manual language version to the comment section (in checkout) when complete the order.

Heating controller for three circuits (control for 2 heating circuits + 1 domestic hot water control). DIN rail mounting. Built in WebServer (WEB UI)

Brochure

WEB UI User Guide ENG

User manual

ENG SWE EST POL LIT LAT

Dimensions: width 213,5 mm, height 93,3 mm, depth 96,8 mm
Weight: 0.7 kg
Protection class: IP 20
Operating temperature: 0 ºC…+40 ºC
Storing temperature: -20 ºC…+70 ºC

Power supply
Operating voltage: 24 Vac, 50 Hz (22 Vac – 33 Vac)
Power required: (15 Vdc output =if not connected) 13 VA, (15 Vdc output = 750 mA) 34 VA
In addition, the operating voltage of 24 Vac and the power requirement of the Triac outputs must be taken into attention. Maximum total current limit is 4A. Then maximum supply power need is 96 VA. (Max 1A/triac pair)
Backup input: 12 Vdc
Current consumption: 300mA / 3,6W (relays not in use), 400mA / 4,8W (relays in use)

Universal measurement input (can be configured) measurement types:
Passive sensors (inputs 1…13) Measurement channel accuracy:
NTC10: +0,1 ºC between -50 ºC…+100 ºC , +0,25 ºC between +100 ºC…+130 ºC.
NTC 1.8 +0,2 ºC between -20 ºC…+40 ºC, +0,6 ºC between +40°C…+70 ºC and +2.0 temp. over 75°C.
NTC 2.2: +0,2 ºC between -20 ºC…+55 ºC, +0,5 ºC between +60°C…+70 ºC and +2.0 temp. over 75°C.
NTC 20: +0,1 ºC between -20 ºC…+70 ºC, +0,6 ºC between +75ºC…+120° C.
Ni1000 LG: +1,0 ºC between -50 ºC…+130 ºC.
Ni1000DIN: +0,2 ºC between 100 ºC…+130 ºC, +0,5 ºC between -5 ºC…-20 ºC.
PT1000 element: +1,0 ºC between -50 ºC…+130 ºC.
Also sensor tolerances and the effect of cables must be considered when calculating total accuracy. Active sensors (inputs 4, 7, 12-14): 0…10 V voltage message, meas. accuracy 1 mV, Milliampere signal with 250Ω shunt resistor 0-20 mA.
Contact information (inputs 10…16): Contact voltage 5 Vdc. Contact current 0,5 mA, Contact resistance max 1,9 kΩ (closed), min 11 kΩ (open)
Digital input measurement types:
Contact i nformation (inputs 21 and 22): Contact voltage 15 Vdc. Contact current 1,5 mA. Contact resistance max 500 Ω (closed), min 1,6 kΩ (open)
Counter inputs (inputs 21…22): Minimum pulse length 30 ms
Analog outputs (61…66): Output voltage range 0…10 V. Output current max 10 mA/output.
Relay output
Change-over contact relay (71…76): 2 pcs, 230 V, 6 A
Normally open contact relay (77…84): 4 pcs, 230 V, 6 A
Triac outputs
24 Vac (42 and 43): Output current together max 1 A
24 Vac (44 and 45): Output current together max 1 A
Operating voltage outputs
5 pcs 24 Vac outputs (41): Output current max 1 A/output
15 Vdc output: Output current max 750 mA
Data transfer connections
– RS-485 bus (A1 and B1): Galvanically isolated, supported protocols Modbus-RTU (COM2, Modbus master)
– RS-485 bus (A2 and B2): Galvanically isolated, supported protocols Modbus-RTU (COM3, Modbus slave)
– USB-host connection: RS-232-modem (GSMMOD)
– Ethernet: Full-duplex 10/100 Mbit/s, supported protocols Modbus-TCP/IP
– Ouman Access: Intelligent remote connection built-in for use with Ounet.

APPROVAL
EMC directive: 2014/30/EU
Interference tolerance: EN 61000-6-1
Interference emissions: EN 61000-6-3