H21

OMA0692

830,00  VAT 0%

In stock (can be backordered)

The Ouman H21 is a surface mounting heating controller for one circuit. It is suitable for radiator heating and floor heating.

User manual

ENG DE CZE FR NO EST SWE

EDP (environmental product declaration)

ENG

Dimensions: width 230 mm, height 160 mm, depth 60 mm
Weight: 1.3 kg
Protection class: IP 41
Operating temperature: 0 ºC…+50 ºC
Storing temperature: -20 ºC…+70 ºC
Power supply L (91), N (92)
Operating voltage: 230 Vac / 200 mA
The internal 24 V power source, total load capacity of max.: 1A/23 VA
Supply cable fuse: max 10A
Measurements inputs:
Sensor measurements (inputs 11-19): NTC10-element: ±0,2 ºC between -50 ºC…+70 ºC
Also sensor tolerances and the effect of cables must be considered when calculating total accuracy. Measurement M1 can be connected also from outside of the casing by a plug-connector.
Digital inputs (27, 28): Contact voltage 15 Vdc, switching current 5 mA. Transfer resistance max. 250 Ω (closed), min. 350 Ω (open).
Analog outputs (68): Output voltage range 0…10 V. Output current max. 7mA
24 VAC output (51): Total current of 24 VAC output and triac-outputs max. 1A.
Pump control contacts (84,85): Contacts for circulation pump. Pumps are controlled by a switch on the top of the H21 device. Relay max. load 3A.
Protective earth terminal (73-78): Protective earth terminal block for 230V devices. Control circuit fuse max. 10A
Control outputs (51): 24 VAC -control output
– Triac (55…60): Total current of triac-outputs and 24 VAC output max. 1A.
Data transfer connections:
– RS-485-bus A (3) and B (6): Unisolated, supported protocols Modbus-RTU.
Options
M-LINK: M-LINK adapter provides Modbus TCP / IP interface for H21
device.
GSMMOD: By connecting the GSM modem to the H21, you can communicate with the text messages to device and receive alarms to GSM phone.

APPROVALS
– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Restriction of Hazardous Substances (RoHS) Directive: 2011/65/EU

The following harmonised standards and technical specifications have been applied:
– LVD: EN 60730-1: 2011, EN 62233: 2008
– EMC: EN 60730-1:2011, EN 61000-3-2:2014, EN 61000-3-3:2013